Basic Specifications: |
Input | Unipolar dc current or voltage |
| Voltage | : 0 - 50mV to 0 - 500V dc |
| Current | : 0 - 10mA to 0 - 5A dc |
Output | Load independent unidirectional dc current or voltage |
| Standard outputs | : 0 - 10mA dc <1500Ω load |
| (others on request) | : 0 - 20mA dc <750Ω load |
| | : 4 - 20mA dc <750Ω load |
| | : 0 - 5V dc >2kΩ load |
| | : 0 - 10V dc >2kΩ load |
Accuracy | | : Class 0.5 to IEC 60688 |
| Range | : 0 to 120% of nominal input |
Auxiliary Supply | | : 24V, 110V, 230/240V, 400/415V ac ±20%, 2VA |
| | : 12V, 24V, 48V, 110V dc ±20%, 2W |
Isolation | Galvanic isolation between input, output circuit and auxiliary supply |
| Test voltage | : 4kV 50Hz ac for 1 minute |
Temperature | Operating | : -10°C to +20°C to +50°C |
EMC Compliance | : AS/NZS 61000.6.3:2012 |